Products > Protein Technology Equipments > Molecular Premium 150 Protein Purifier

Molecular Premium 150 Protein Purifier

Protein Purification System、Protein Purifier、AKTA Purifier、Cytiva Purifier

I. Main machine

*1.Automatic micro piston pump, the pump head is made of titanium alloy, double pump and four pump heads, and the pump heads have independent degasing valves; High voltage withstand

*2.The flow rate of single pump ranges from 0.01mL/min to 150mL/min, the column can be installed in double pump mode, the maximum flow rate is ≥300mL/min;

3.Pressure range 0~5MPa;

*4.Flow rate accuracy ≤1% (flow rate range 1.0mL/min ~120mL/min, pressure < 3MPa, viscosity range 0.8cP ~2cP);

5.With constant pressure speed regulation function;

★6.Xenon lamp light source, no need to change the lamp and preheating when UV/visible light switch;

7.Full wavelength detector, wavelength range 190nm~700nm;

8.Detection range: -5AU~+5AU, deviation ≤2% (0~2AU);

*9.Light source and flow pool are designed separately; Avoid the influence of light source overheating on the sample, high accuracy. When the pump is turned on, the lamp is turned on, effectively extending the UV life.

10.Conductivity detection range: 0.001mS/cm ~ 999.99mS/cm, conductivity accuracy ≤±0.01mS/cm

11.UV detector and conductivity detector are designed separately;

12.Temperature detection range: 0~99℃, accuracy ≤±2℃ (4℃~45℃);

13.Supporting pH valve (including pH electrode), can be online pH monitoring (pH range 0-14), accuracy ≤±0.1 (pH range 0-14);

14.Buffer selection valve: inlet number ≥8, built-in bubble sensor to protect the chromatographic column;

*15.Five-column position valve: automatically select 5 chromatographic columns, another path is included for system cleaning, and has the function of positive and negative flow direction control, built-in pressure sensors before and after the column to protect the chromatographic column and packing;

*16.Equipped with separate sample pump.

Twelve-way collection valve: one position is connected to the collector to achieve the collection of a larger number of samples, one position is connected to the waste liquid, and the rest of the outlet can achieve the collection of large volume valves.

Collector: Can be automatically collected according to volume or peak: collection range from 0.1ml to 50ml. Compatible with 1.5,5,15,50ml collection tubes.

II. Software:

17.The purification process can be controlled in real time;

18.System management module: Controls different hardware modules;

19.Method Editor module: allows users to create or adjust predefined test methods;

20.System control module: provides an overview of the operating status;

21 Result analysis module: it can realize rapid analysis, result comparison and analysis of peaks and components;

22 Built-in chromatographic column and gel filler (compliant with FDA standards) information.

III. Computer workstation

23 Windows operating system


Name
Phone
Email
Corporate name
Address
Leaving Message*
 
Verification code
Submit